1-832-478-9159 Monday - Friday 9 am - 5 pm

Dell PowerEdge R720xd Server

SKU: Dell-R720xd-12B-LFF

Chassis
Qty
Price
12 Bay LFF
1
$649.99
Price as configured
Regular price
$649.99
Sale price
$649.99
Unit price
per 

Cloud Ninjas' Dell PowerEdge R720xd Specifications

Chassis

The Dell PowerEdge R720xd server is an excellent solution for storage applications. The R720xd provides more drive bays than the R720. There is a total of two chassis options for the PowerEdge R720xd server: 12 Bay LFF and 24 Bay SFF. The differences between each chassis have to do with the number of drive bays as well as the form factor of those drive bays.

12 Bay LFF

The 12 Bay LFF chassis for the R720xd accepts up to twelve 3.5" SAS/SATA hard drives. 2.5" HDDs and SSDs can be installed with using a 2.5" to 3.5" drive converter. This chassis is also equipped with two rear 2.5" drive bays. There are three low-profile and three full-height PCIe slots.

24 Bay SFF

The 24 Bay SFF chassis supports up to twenty-four 2.5" SAS/SATA hard drives and/or SSDs. Just like the 12 Bay LFF chassis, the 24 Bay SFF chassis has two rear 2.5" drive bays. There are also three low-profile and three full-height PCIe slots.

Processing Power

The Dell PowerEdge R720xd server is a dual processor system that accepts Intel Xeon E5-2600 or E5-2600v2 Processors. In order to use an E5-2600v2 processor, you may have to update your server’s BIOS. Each socket is an LGA2011 socket that supports up to 12 cores per socket. A total of 24 cores be installed. One thing to note is, that in order to use Intel Xeon E5-2600v2 series processor with the R720xd, you must have an up to date BIOS.

Intel Xeon E5-2600 Series Processors

CPU Step Code Cores Frequency
E5-2603 SR0LB 4 1.80 GHz
E5-2609 SR0LA 4 2.40 GHz
E5-2620 SR0KW 6 2.00 GHz
E5-2630 SR0KV 6 2.30 GHz
E5-2630L SR0KM 6 2.00 GHz
E5-2637 SR0LE 2 3.00 GHz
E5-2640 SR0KR 6 2.50 GHz
E5-2643 SR0L7 4 3.30 GHz
E5-2648L SR0LX 8 1.80 GHz
E5-2650 SR0KQ 8 2.00 GHz
E5-2650L SR0KL 8 1.80 GHz
E5-2658 SR0LZ 8 2.10 GHz
E5-2660 SR0KK 8 2.20 GHz
E5-2665 SR0L1 8 2.40 GHz
E5-2667 SR0KP 6 2.90 GHz
E5-2670 SR0KX 8 2.60 GHz
E5-2680 SR0KH 8 2.70 GHz
E5-2687W SR0KG 8 3.10 GHz
E5-2690 SR0L0 8 2.90 GHz

Intel Xeon E5-2600 v2 Series Processors

CPU Step Code Cores Frequency
E5-2603v2 SR1AY 4 1.80 GHz
E5-2609v2 SR1AX 4 2.50 GHz
E5-2618Lv2 SR1B8 6 2.00 GHz
E5-2620v2 SR1AN 6 2.10 GHz
E5-2628Lv2 SR1AF 8 1.90 GHz
E5-2630v2 SR1AM 6 2.60 GHz
E5-2630Lv2 SR1AZ 6 2.40 GHz
E5-2637v2 SR1B7 4 3.50 GHz
E5-2640v2 SR19Z 8 2.00 GHz
E5-2643v2 SR19X 6 3.50 GHz
E5-2648Lv2 SR1A2 10 1.90 GHz
E5-2650v2 SR1A8 8 2.60 GHz
E5-2650Lv2 SR19Y 10 1.70 GHz
E5-2658v2 SR1A0 10 2.40 GHz
E5-2660v2 SR1AB 10 2.20 GHz
E5-2667v2 SR19W 8 3.30 GHz
E5-2670v2 SR1A7 10 2.50 GHz
E5-2680v2 SR1A6 10 2.80 GHz
E5-2687Wv2 SR19V 8 3.40 GHz
E5-2690v2 SR1A5 10 3.00 GHz
E5-2695v2 SR1BA 12 2.40 GHz
E5-2697v2 SR19H 12 2.70 GHz

Memory

DIMM Slots & Channels

The Dell PowerEdge R720xd Server has a total of 24 DDR3 DIMM slots. There are 8 memory channels that each consist of 3 DIMM slots.

Memory Types & Module Capacities

The R720xd accepts either ECC Registered Memory (RDIMMs) or Load Reduced Memory (LRDIMMs). You can use capacities of 4GB, 8GB, 16GB, 32GB, and 64GB. Do note that 64GB modules can only be used with Load Reduced memory. Because of this, you can achieve a larger maximum RAM capacity.

Max Configurations

With ECC Registered memory, a max size of 512GB can be reached with a configuration of sixteen 32GB modules. Load Reduced memory on the other hand can reach a max of 1.5TB of RAM with a configuration of twenty-four 64GB modules.

RAM Speeds

The R720xd supports memory speeds of 1066MT/s, 1333MT/s, and 1600MT/s. 1866MT/s modules can be installed, but they will clock down to the true fastest speed of 1600MT/s.

Storage

The R720xd chassis that you have will determine whether you can install 2.5" or 3.5" drives. The R720xd accepts SAS, SATA, and SSD drives. There are also two 2.5" rear drive bays that allow you to install an extra two 2.5" HDDs or SSDs. All chassis options support hot-swap drives, meaning you can remove and/or add drives while the machine is powered on.

Supported Drives

Type Max Capacity (Per 2.5" Drive) Speeds
SAS 2.4 TB 7.2k, 10k, or 15k
SATA 2 TB 7.2k
SSD 7.68 TB 3 GB/s or 6 GB/s
Type Max Capacity (Per 3.5" Drive) Speeds
SAS 16 TB 7.2k, 10k, or 15k
SATA 14 TB 7.2k
SSD 7.68 TB 3 GB/s or 6 GB/s

Power Supplies

How Many Power Supplies does the R720xd Take?

The Dell PowerEdge R720xd Server can hold a maximum of two hot-swap power supplies. Because the power supplies are hot-swap, you can remove one from the system while the server is powered on. This will only work as long as one power supply remains plugged in.

Wattage Options

The R720xd server has three power supply wattage options: 495W, 750W, and 1100W. All three options are great choices, but which one you choose depends on your application. Systems that have high end components generally require more power. Also, if the system is performing resource intensive tasks, then there will be more of a demand for power. In both cases, going with a 750W or 1100W PSU is the way to go.

Voltage

An important thing to pay attention to when buying a power supply for you R720xd, is the voltage. R720xd power supplies can be either 110V or 220V. If you purchase a 220V power supply, but only have a 110V connection, then the system will not power on. Most outlets in American homes are equipped with 110V connections, while homes in Europe use 220V connections. 220V connections are also commonly seen in data centers. Before purchasing a power supply for your server, find out what connection you need, and then make sure the PSU you purchase supports that connection.

RAID Options

RAID Options RAID Levels Cache Drive Speeds PCIe Generation RAID Hardware
S110 onboard software 0,1,5,10 None 3 Gb/s SATA
6 Gb/s SAS
PCIe 2.0 Software
H310 Mini Mono 0,1,5,10,50 None 3 Gb/s SATA
6 Gb/s SAS
PCIe 2.0 Hardware
H710 Mini Mono 0,1,5,6,10,50,60 512MB 3 Gb/s SATA
6 Gb/s SAS
PCIe 2.0 Hardware
H710p Mini Mono 0,1,5,6,10,50,60 1GB 3 Gb/s SATA
6 Gb/s SAS
PCIe 2.0 Hardware
H810 PCIe Adapter 0,1,5,6,10,50,60 1GB 3 Gb/s SATA
6 Gb/s SAS
PCIe 2.0 Hardware

Network Interface Card Options

Daughter Card

Dell Broadcom 5720 Quad Port 4x 1GbE RJ45
Dell Broadcom 57412 Quad Port 2 x 1GbE + 2 x 10 GbE RJ45 SFP+
Dell Broadcom 57416 Quad Port 2 x 1GbE + 2 x 10 GbE RJ45
Dell Broadcom 57800S Quad Port 2x 1GbE 2x 10GbE RJ45 SFP+
Dell Broadcom 57800-T Quad Port 2 x 1GbE + 2 x 10GbE RJ45
Dell Intel I350 Quad Port 4x 1GbE RJ45
Dell Intel I350/X540 Quad Port 2 x 1GbE + 2 x 10GbE RJ45
Dell Intel I350/X710 Quad Port 2 x 1GbE + 2 x 10GbE RJ45 SFP+
Dell Intel X710 Quad Port 4 x 10GbE SFP+

PCIe Card

Dell Broadcom 5719 Quad Port 4x 1GbE RJ45
Dell Broadcom 5720 Dual Port 2 x 1GbE RJ45
Dell Broadcom 5720 Quad Port 4 x 1GbE RJ45
Dell Broadcom 57810S Dual Port 2 x 10GbE SFP+
Dell Intel I350 Dual Port 2 x 1GbE RJ45
Dell Intel I350-T2 Dual Port 2 x 1GbE RJ45
Dell Intel I350-T4 Quad Port 4 x 1GbE RJ45
Dell Intel X520-DA2 Dual Port 2 x 10GbE SFP+

Supported Operating Systems:

The PowerEdge R720xd supports a wide variety of operating systems which ranges from different distributions of Linux, VMware, and Windows Server. These operating systems are:

  • ⦿ Citrix XenServer 6.0
  • ⦿ Citrix XenServer 6.1
  • ⦿ Citrix XenServer 6.2
  • ⦿ Citrix XenServer 6.5
  • ⦿ Citrix XenServer 7.0
  • ⦿ Novell SuSE Lunix ES 11
  • ⦿ Red Hat Ent Linux 5
  • ⦿ Red Hat Ent Virtual3
  • ⦿ Red Hat Enterprise Linux 6
  • ⦿ Red Hat Enterprise Linux 7
  • ⦿ Suse Linux ES 10
  • ⦿ SUSE Linux ES 12
  • ⦿ VMware ESX 4.1
  • ⦿ VMware ESXI 4.1
  • ⦿ VMware ESXI 5.0
  • ⦿ VMware ESXI 5.1
  • ⦿ VMware ESXI 5.5
  • ⦿ VMware ESXI 6.0
  • ⦿ VMware ESXI 6.5
  • ⦿ Windows Server 2008 R2
  • ⦿ Windows Server 2008 x64
  • ⦿ Windows Server 2008 x86
  • ⦿ Windows Server 2012
  • ⦿ Windows Server 2012 R2
  • ⦿ Windows Server 2016

Dell PowerEdge R720xd Video

Technical Information Overview

The Dell PowerEdge R720xd 2U Rackmount Server is loaded with options and features which is great in terms of customization and scalability. With the great capabilities of the PowerEdge R720xd, it can be hard to navigate. Because of this we have group together manuals and guides directly from Dell, so you have all the information you need to configure, upgrade, or troubleshoot your Dell PowerEdge R720xd Server.

Owner’s Manual

Learn the ins and outs of your R720xd with the Owner’s Manual: View PowerEdge R720xd Owner’s Manual

Technical Guide

Need help troubleshooting your R720xd? The R720xd technical guide is a great place to start: View PowerEdge R720xd Technical Guide

Setting Up Your System Using Lifecycle Controller

Learn how to manage your PowerEdge R720xd via iDRAC7 and Lifecycle Controller: View PowerEdge R720xd iDRAC7 and Lifecycle Controller Guide

BIOS Upgrade EFI Download

Upgrade your BIOS Via an EFI BIOS File: Download PowerEdge R720xd BIOS Upgrade EFI File

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

CPUs

Memory

Drives

NVMe

Coming Soon

Different Chassis Types

RAID

BIOS

iDRAC

Mass Updates

How to set IP Address

How to install VMware ESXI 7.0.3

Network Cards

Power Supplies

How to Rack

How to Install Windows Server 2016

Cloud Ninjas' Dell PowerEdge R720xd Specifications

Chassis

The Dell PowerEdge R720xd server is an excellent solution for storage applications. The R720xd provides more drive bays than the R720. There is a total of two chassis options for the PowerEdge R720xd server: 12 Bay LFF and 24 Bay SFF. The differences between each chassis have to do with the number of drive bays as well as the form factor of those drive bays.

12 Bay LFF

The 12 Bay LFF chassis for the R720xd accepts up to twelve 3.5" SAS/SATA hard drives. 2.5" HDDs and SSDs can be installed with using a 2.5" to 3.5" drive converter. This chassis is also equipped with two rear 2.5" drive bays. There are three low-profile and three full-height PCIe slots.

24 Bay SFF

The 24 Bay SFF chassis supports up to twenty-four 2.5" SAS/SATA hard drives and/or SSDs. Just like the 12 Bay LFF chassis, the 24 Bay SFF chassis has two rear 2.5" drive bays. There are also three low-profile and three full-height PCIe slots.

Processing Power

The Dell PowerEdge R720xd server is a dual processor system that accepts Intel Xeon E5-2600 or E5-2600v2 Processors. In order to use an E5-2600v2 processor, you may have to update your server’s BIOS. Each socket is an LGA2011 socket that supports up to 12 cores per socket. A total of 24 cores be installed. One thing to note is, that in order to use Intel Xeon E5-2600v2 series processor with the R720xd, you must have an up to date BIOS.

Intel Xeon E5-2600 Series Processors

CPU Step Code Cores Frequency
E5-2603 SR0LB 4 1.80 GHz
E5-2609 SR0LA 4 2.40 GHz
E5-2620 SR0KW 6 2.00 GHz
E5-2630 SR0KV 6 2.30 GHz
E5-2630L SR0KM 6 2.00 GHz
E5-2637 SR0LE 2 3.00 GHz
E5-2640 SR0KR 6 2.50 GHz
E5-2643 SR0L7 4 3.30 GHz
E5-2648L SR0LX 8 1.80 GHz
E5-2650 SR0KQ 8 2.00 GHz
E5-2650L SR0KL 8 1.80 GHz
E5-2658 SR0LZ 8 2.10 GHz
E5-2660 SR0KK 8 2.20 GHz
E5-2665 SR0L1 8 2.40 GHz
E5-2667 SR0KP 6 2.90 GHz
E5-2670 SR0KX 8 2.60 GHz
E5-2680 SR0KH 8 2.70 GHz
E5-2687W SR0KG 8 3.10 GHz
E5-2690 SR0L0 8 2.90 GHz

Intel Xeon E5-2600 v2 Series Processors

CPU Step Code Cores Frequency
E5-2603v2 SR1AY 4 1.80 GHz
E5-2609v2 SR1AX 4 2.50 GHz
E5-2618Lv2 SR1B8 6 2.00 GHz
E5-2620v2 SR1AN 6 2.10 GHz
E5-2628Lv2 SR1AF 8 1.90 GHz
E5-2630v2 SR1AM 6 2.60 GHz
E5-2630Lv2 SR1AZ 6 2.40 GHz
E5-2637v2 SR1B7 4 3.50 GHz
E5-2640v2 SR19Z 8 2.00 GHz
E5-2643v2 SR19X 6 3.50 GHz
E5-2648Lv2 SR1A2 10 1.90 GHz
E5-2650v2 SR1A8 8 2.60 GHz
E5-2650Lv2 SR19Y 10 1.70 GHz
E5-2658v2 SR1A0 10 2.40 GHz
E5-2660v2 SR1AB 10 2.20 GHz
E5-2667v2 SR19W 8 3.30 GHz
E5-2670v2 SR1A7 10 2.50 GHz
E5-2680v2 SR1A6 10 2.80 GHz
E5-2687Wv2 SR19V 8 3.40 GHz
E5-2690v2 SR1A5 10 3.00 GHz
E5-2695v2 SR1BA 12 2.40 GHz
E5-2697v2 SR19H 12 2.70 GHz

Memory

DIMM Slots & Channels

The Dell PowerEdge R720xd Server has a total of 24 DDR3 DIMM slots. There are 8 memory channels that each consist of 3 DIMM slots.

Memory Types & Module Capacities

The R720xd accepts either ECC Registered Memory (RDIMMs) or Load Reduced Memory (LRDIMMs). You can use capacities of 4GB, 8GB, 16GB, 32GB, and 64GB. Do note that 64GB modules can only be used with Load Reduced memory. Because of this, you can achieve a larger maximum RAM capacity.

Max Configurations

With ECC Registered memory, a max size of 512GB can be reached with a configuration of sixteen 32GB modules. Load Reduced memory on the other hand can reach a max of 1.5TB of RAM with a configuration of twenty-four 64GB modules.

RAM Speeds

The R720xd supports memory speeds of 1066MT/s, 1333MT/s, and 1600MT/s. 1866MT/s modules can be installed, but they will clock down to the true fastest speed of 1600MT/s.

Storage

The R720xd chassis that you have will determine whether you can install 2.5" or 3.5" drives. The R720xd accepts SAS, SATA, and SSD drives. There are also two 2.5" rear drive bays that allow you to install an extra two 2.5" HDDs or SSDs. All chassis options support hot-swap drives, meaning you can remove and/or add drives while the machine is powered on.

Supported Drives

Type Max Capacity (Per 2.5" Drive) Speeds
SAS 2.4 TB 7.2k, 10k, or 15k
SATA 2 TB 7.2k
SSD 7.68 TB 3 GB/s or 6 GB/s
Type Max Capacity (Per 3.5" Drive) Speeds
SAS 16 TB 7.2k, 10k, or 15k
SATA 14 TB 7.2k
SSD 7.68 TB 3 GB/s or 6 GB/s

Power Supplies

How Many Power Supplies does the R720xd Take?

The Dell PowerEdge R720xd Server can hold a maximum of two hot-swap power supplies. Because the power supplies are hot-swap, you can remove one from the system while the server is powered on. This will only work as long as one power supply remains plugged in.

Wattage Options

The R720xd server has three power supply wattage options: 495W, 750W, and 1100W. All three options are great choices, but which one you choose depends on your application. Systems that have high end components generally require more power. Also, if the system is performing resource intensive tasks, then there will be more of a demand for power. In both cases, going with a 750W or 1100W PSU is the way to go.

Voltage

An important thing to pay attention to when buying a power supply for you R720xd, is the voltage. R720xd power supplies can be either 110V or 220V. If you purchase a 220V power supply, but only have a 110V connection, then the system will not power on. Most outlets in American homes are equipped with 110V connections, while homes in Europe use 220V connections. 220V connections are also commonly seen in data centers. Before purchasing a power supply for your server, find out what connection you need, and then make sure the PSU you purchase supports that connection.

RAID Options

RAID Options RAID Levels Cache Drive Speeds PCIe Generation RAID Hardware
S110 onboard software 0,1,5,10 None 3 Gb/s SATA
6 Gb/s SAS
PCIe 2.0 Software
H310 Mini Mono 0,1,5,10,50 None 3 Gb/s SATA
6 Gb/s SAS
PCIe 2.0 Hardware
H710 Mini Mono 0,1,5,6,10,50,60 512MB 3 Gb/s SATA
6 Gb/s SAS
PCIe 2.0 Hardware
H710p Mini Mono 0,1,5,6,10,50,60 1GB 3 Gb/s SATA
6 Gb/s SAS
PCIe 2.0 Hardware
H810 PCIe Adapter 0,1,5,6,10,50,60 1GB 3 Gb/s SATA
6 Gb/s SAS
PCIe 2.0 Hardware

Network Interface Card Options

Daughter Card

Dell Broadcom 5720 Quad Port 4x 1GbE RJ45
Dell Broadcom 57412 Quad Port 2 x 1GbE + 2 x 10 GbE RJ45 SFP+
Dell Broadcom 57416 Quad Port 2 x 1GbE + 2 x 10 GbE RJ45
Dell Broadcom 57800S Quad Port 2x 1GbE 2x 10GbE RJ45 SFP+
Dell Broadcom 57800-T Quad Port 2 x 1GbE + 2 x 10GbE RJ45
Dell Intel I350 Quad Port 4x 1GbE RJ45
Dell Intel I350/X540 Quad Port 2 x 1GbE + 2 x 10GbE RJ45
Dell Intel I350/X710 Quad Port 2 x 1GbE + 2 x 10GbE RJ45 SFP+
Dell Intel X710 Quad Port 4 x 10GbE SFP+

PCIe Card

Dell Broadcom 5719 Quad Port 4x 1GbE RJ45
Dell Broadcom 5720 Dual Port 2 x 1GbE RJ45
Dell Broadcom 5720 Quad Port 4 x 1GbE RJ45
Dell Broadcom 57810S Dual Port 2 x 10GbE SFP+
Dell Intel I350 Dual Port 2 x 1GbE RJ45
Dell Intel I350-T2 Dual Port 2 x 1GbE RJ45
Dell Intel I350-T4 Quad Port 4 x 1GbE RJ45
Dell Intel X520-DA2 Dual Port 2 x 10GbE SFP+

Supported Operating Systems:

The PowerEdge R720xd supports a wide variety of operating systems which ranges from different distributions of Linux, VMware, and Windows Server. These operating systems are:

  • ⦿ Citrix XenServer 6.0
  • ⦿ Citrix XenServer 6.1
  • ⦿ Citrix XenServer 6.2
  • ⦿ Citrix XenServer 6.5
  • ⦿ Citrix XenServer 7.0
  • ⦿ Novell SuSE Lunix ES 11
  • ⦿ Red Hat Ent Linux 5
  • ⦿ Red Hat Ent Virtual3
  • ⦿ Red Hat Enterprise Linux 6
  • ⦿ Red Hat Enterprise Linux 7
  • ⦿ Suse Linux ES 10
  • ⦿ SUSE Linux ES 12
  • ⦿ VMware ESX 4.1
  • ⦿ VMware ESXI 4.1
  • ⦿ VMware ESXI 5.0
  • ⦿ VMware ESXI 5.1
  • ⦿ VMware ESXI 5.5
  • ⦿ VMware ESXI 6.0
  • ⦿ VMware ESXI 6.5
  • ⦿ Windows Server 2008 R2
  • ⦿ Windows Server 2008 x64
  • ⦿ Windows Server 2008 x86
  • ⦿ Windows Server 2012
  • ⦿ Windows Server 2012 R2
  • ⦿ Windows Server 2016

Dell PowerEdge R720xd Video

Technical Information Overview

The Dell PowerEdge R720xd 2U Rackmount Server is loaded with options and features which is great in terms of customization and scalability. With the great capabilities of the PowerEdge R720xd, it can be hard to navigate. Because of this we have group together manuals and guides directly from Dell, so you have all the information you need to configure, upgrade, or troubleshoot your Dell PowerEdge R720xd Server.

Owner’s Manual

Learn the ins and outs of your R720xd with the Owner’s Manual: View PowerEdge R720xd Owner’s Manual

Technical Guide

Need help troubleshooting your R720xd? The R720xd technical guide is a great place to start: View PowerEdge R720xd Technical Guide

Setting Up Your System Using Lifecycle Controller

Learn how to manage your PowerEdge R720xd via iDRAC7 and Lifecycle Controller: View PowerEdge R720xd iDRAC7 and Lifecycle Controller Guide

BIOS Upgrade EFI Download

Upgrade your BIOS Via an EFI BIOS File: Download PowerEdge R720xd BIOS Upgrade EFI File

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Cloud Ninja One Year Warranty

WHAT IS COVERED BY THIS WARRANTY?

Cloud Ninja warrants the hardware product and accessories contained in the original packaging (“Cloud Ninja Product”) against defects in materials and workmanship when used normally in accordance with Cloud Ninja' guidelines for a period of ONE (1) YEAR from the date of original retail purchase by the end-user purchaser ("Warranty Period"). Cloud Ninja’s guidelines include but are not limited to information contained in technical specifications and user manuals communications from Brand.

Please note: All claims made under the Cloud Ninja’s One-Year Limited Warranty will be governed by the terms set out in this warranty document.

WHAT IS NOT COVERED BY THIS WARRANTY?

This Warranty does not apply to any non-Cloud Ninja sold hardware products or any software, even if packaged or sold with Cloud Ninja hardware. Manufacturers, suppliers, or publishers, other than Cloud Ninjas, may provide their own warranties to you – please contact them for further information. Cloud Ninjas does not warrant that the operation of the Cloud Ninja Product will be uninterrupted or error-free. Cloud Ninjas is not responsible for damages arising from failure to follow instructions relating to the Cloud Ninja Product’s use. We do warranty drives used for China plotting or mining. We support the Crypto community and love what they are building. However, China burns through drives and we cannot provide warranty for China.

This Warranty does not apply: (a) to consumable parts, such as batteries or protective coatings that are designed to diminish over time, unless failure has occurred due to a defect in materials or workmanship; (b) to cosmetic damage, including but not limited to scratches, dents and broken plastic on ports; (c) to damage caused by use with another product; (d) to damage caused by accident, abuse, misuse, liquid contact, fire, earthquake or other external cause; (e) to damage caused by operating the Cloud Ninjas Product outside original manufacturer’s published guidelines; (f) to damage caused by service (including upgrades and expansions) performed by anyone who is not a representative of Cloud Ninjas or a Cloud Ninjas Authorized Service Provider; (g) to a Cloud Ninjas Product that has been modified to alter functionality or capability without the written permission of Cloud Ninjas; (h) to defects caused by normal wear and tear or otherwise due to the normal aging of the Cloud Ninjas Product, or (i) if any serial number has been removed or defaced from the Cloud Ninjas Product.

YOUR RESPONSIBILITIES

YOU SHOULD MAKE PERIODIC BACKUP COPIES OF THE INFORMATION CONTAINED ON THE CLOUD NINJAS PRODUCT STORAGE MEDIA TO PROTECT THE CONTENTS AND AS A PRECAUTION AGAINST POSSIBLE OPERATIONAL FAILURES.

Before receiving warranty service, Cloud Ninjas or its agents may require that you furnish proof of purchase details, respond to questions designed to assist with diagnosing potential issues and follow Cloud Ninjas’ procedures for obtaining warranty service. Before submitting your Cloud Ninjas Product for warranty service you should maintain a separate backup copy of the contents of its storage media, remove all personal information that you want to protect and disable all security passwords.

DURING WARRANTY SERVICE IT IS POSSIBLE THE CONTENTS OF THE STORAGE MEDIA WILL BE LOST, REPLACED OR REFORMATTED. CLOUD NINJAS AND ITS AGENTS ARE NOT RESPONSIBLE FOR ANY LOSS OF SOFTWARE PROGRAMS, DATA OR OTHER INFORMATION CONTAINED ON THE STORAGE MEDIA OR ANY OTHER PART OF THE CLOUD NINJAS PRODUCT SERVICED.

Following warranty service your Cloud Ninjas Product or a replacement device will be returned to you as your Cloud Ninja Product was configured when originally purchased, subject to applicable updates. You will be responsible for reinstalling all other software programs, data and information. Recovery and reinstallation of other software programs, data and information are not covered under this Warranty.

You may also be interested in the following product(s)